Overview
Sale Leica TS15 1” R400 Robotic Total Station including CS15 Field Controller with TPS Radio. Used and everything is in full working order and excellent cosmetic condition. Fully serviced and calibrated by Leica authorized.
Sell used Leica TS15 includes:
- Leica TS15 1” R400 Total Station
- Tribrach
- GEB221 battery for TS15
- Charger
- Radio Handle(RH15)
- Hard case for TS15
- Leica CS15 Field Controller with TPS Radio
- 2x Batteries for Leica CS15
- Pole Holder
- Hard case for Leica CS15
TS15A Features:
- Angle measurement
- Distance measurement to prism
- Distance measurement to any surface (reflectorless)
- Motorized
- Automatic Target Aiming
- RS232, USB and SD card interface
- Bluetooth
- Internal Flash Memory (1GB)
- Hotshoe interface for radiohandle
- Guide Light (EGL)
- SmartStation/SmartPole GS15 GNSS receiver (Optional)
- SmartStation/SmartPole GS14 GNSS receiver (Optional)
- SmartStation/SmartPole GS12 GNSS receiver (Optional)
- Radio field controller CS10/CS15 (Optional)
Spesification
| General | |
| Telescope |
|
| Processor | Freescale i.MX31 533 MHz ARM Core |
| Operating System | Windows CE 6.0 |
| Display | 640 x 480 pixel (VGA) color TFT with LED backlight and touch screen |
| Keyboard | 36 keys (12 function keys, 12 alphanumeric keys), illumination |
| Internal memory | 1 GB (nonvolatile NAND Flash) |
| Memory devices | SD card, USB stick |
| Interfaces | RS232, Bluetooth® Wireless-Technology, USB mini AB OTG |
| Sensitivity of Circular Level | 6’ / 2 mm |
| Centering accuracy of Laser plummet | 1.5 mm at 1.5 m |
| Internal Battery | Lithium Ion |
| Operating Time | 5 – 8 h (GEB221) |
| Voltage | 7.4 V |
| Capacity | 4.4 Ah |
| Dimension | 345 x 226 x 203 mm |
| Weight |
|
| Environmental specifications |
|
| Working Range | 5 – 150 m |
| Positioning accuracy | 5 cm at 100 m |
| Angular Measurement | |
| Accuracy Hz, V | 1’’ (0.3 mgon), 2’’ (0.6 mgon), 3’’ (1 mgon), 5’’ (1.5 mgon) |
| Display resolution | 0.1’’ (0.1 mgon) |
| Method | Absolute, continuous, diametrical |
| Compensation | Quadruple axis compensation |
| Compensator setting accuracy | 0.5’’ (0.2 mgon), 0.5’’ (0.2 mgon), 1.0’’ (0.3 mgon), 1.5’’ (0.5 mgon) |
| Distance Measurement | |
| Distance Measurement (Prism) | Range
Accuracy / Measurement Time
|
| Distance Measurement (Any Surface) | Range PinPoint R400: 400 m (1310 ft)
Accuracy / Measurement Time: 2 mm + 2 ppm / typ. 3 s |
| Distance Measurement (Long-range) | |
| Long-range | >10000 m (>32800 ft) |
| Accuracy / Measurement Time | Long-range: 5 mm + 2 ppm / typ. 2.5 s |
| General |
|