Trimble MS992 GCS900 GPS GNSS CB460 SNR930 Kit for sale, this kit is in great tested, service and calibrated by Trimble to be ready to working on the field
Condition: Used
Up for sale a used Trimble MS992 GCS900 GPS GNSS CB460 SNR930 Kit, this kit is in great tested, service and calibrated by Trimble to be ready to working on the field. This system is compatible with CAT Accugrade, Trimble Base Stations, and GCS900 Machine Control Systems. This kit is in great tested condition with 6 months warrrantyu and 30 days money back guarantee.
This Includes:
The MS992 is available in single or dual configurations on the following machine types:
Key Features & Benefits
Performance Characteristic:
Tracking and performance
Measurements
Trimble MS992 Specifications
| Code differential Positioning | Horizontal accuracy: 8 mm + 1 ppm RMS (0.032 ft + 1 ppm RMS) |
| Vertical accuracy: 15 mm + 1 ppm RMS (0.065 ft +1 ppm RMS) | |
| Real Time Kinematic (RTK) positioning | Horizontal accuracy: 8 mm + 0.5 ppm RMS (0.032 ft +0.5 ppm) |
| Vertical accuracy: 15 mm + 0.5 ppm RMS (0.05 ft +0.5 ppm) | |
| Initialization time | Typically2 < 10 seconds + 0.5 times baseline length in km, up to 30 km (Regular RTK operation with base station) |
| Initialization Reliability | Typically3 > 99.9% |
| Physical Characteristics | |
| Size (H x W x D) | 147 mm x 231.9 mm x 251.1 mm |
| Weight | 3.8 kg with mounting bracket |
| Mounting | Mast Mounting Bracket |
| Network Connector | 16 pin Amphenol bayonet, sealed |
| Indicators (3 yellow LEDs) | Upper: DC Power |
| Middle: GPS correction signal status (via radio link or cable) | |
| Lower: GNSS signal status (no signal, searching, or tracking) | |
| Environmental Characteristics | |
| Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
| Storage Temperature | -50°C to +85°C (-67°F to +185°F) |
| Humidity | Waterproof, 100% fully sealed |
| Sealing | +/- 5 psi sealing |
| Shock | 75 Gs, 6 milliseconds duration, 3 shocks in each of the three mutually perpendicular axes |
| Vibration | 20.4 gRMS |
| :EMC | EN13309:2000, CE Mark, C-Tick |
| Technical Specifications | |
| Electrical Input Voltage | 9 to 32 VDC |
| Electrical Input Power | 18W maximum; 5W nominal |
| Control Interface | J1939 CAN network (two buses) |
| RS-232 Serial (two ports) | |
| Reverse Voltage Protection | Load Dump Protection: Yes |
| Tracking: Yes | |