Leica TCRP1203 Pluss R400 Robotic Total Station

Sell used Total Station Robotic Leica TCRP 1203+ R400 EDM, ATR, PS RH1617

$2,700

Up for sale Pre-owned Leica TCRP 1203+ R400 EDM, ATR, PS RH1617, robotic, 3″ total station in excellent condition. Instrument has been fully reconditioned. It’s been disassembled by a service technician, drive gears cleaned & lubed, any worn parts replaced, everything brought back to original factory specs. Certificate of calibration will be provided upon request.

Sale used Leica TCRP1203  includes:

  • 1X Leica TCRP 1203+ R400
  • 1X Battery
  • 1X Charging
  • 1X Case

Highest accuracy Longest range
TPS1200’s precision angle-measurement system operates continuously providing instant horizontal and vertical circle readings that are automatically corrected for any “out of level” by a centrally located twin-axis compensator.
The coaxial EDM uses an infrared laser, has various measuring modes, and measures to prisms and reflective tape.
The range is excellent – 3 km to a single prism – and the accuracy superb – 2 mm + 2 ppm. Resolution is 0.1 mm.

  • Fast, continuous, high-accuracy angle measurements
  • Choice of accuracy from 1 to 5 seconds
  • No initialization
  • Twin-axis compensator
  • EDM with standard, fast and tracking modes
  • Long range, fast measurements and high accuracy
  • Totally reliable
     

Measure points quick and accurate
With ATR, you only need to point roughly and take a measurement; TPS1200 then fine points to the center of the prism and measures, all fully automatically. In LOCK mode TPS1200 remains locked onto the reflector and follows it as it moves.
Measurements can be taken at any time. And, as software predicts reflector movements, TPS1200 continues to track in spite of obstructions and short interruptions. If long interruptions should cause complete loss of lock, use PowerSearch.

  • Optional for motorized TPS1200
  • Eliminates manual operation
  • Very fast measurements
  • Uniform high accuracy
  • Works with standard prisms (no need for active target)

 

Packed with exciting new features, built for speed, accuracy, ease-of-use and reliability. Leica TPS1200 Total Stations carry out even the most complex tasks, better and more efficiently than ever before. And, best of all, they combine perfectly with GPS.

Superb measurement technology
High accuracy angle measurements and precise long-range distance measurements backed by automatic fine pointing and fast, reliable reflector location. You work faster, more precisely and more relaxed.

Easy to operate
Intuitive interface, powerful data management, on-board routines and programs: all easy to use and identical for TPS and GPS.

Large graphic display
Easy viewing of entire surveyed area and immediate access to all measured data. You see exactly what you’ve done and what you’ve still to do.

Totally flexible
Configure and program TPS1200 in the way you want, for your applications, for the way you work and for the data output you require.

A complete series
TPS1200 total stations cover a range of models and options. Select the ones that suit you best.

Use TPS1200 for everything
Use TPS1200 total stations for surveying, engineering, stakeout, topo, monitoring etc. Combine them with GPS. Benefit from huge productivity of System 1200.

Features:

  • Angle measurement
  • Distance measurement (IR)
  • PinPoint reflectorless dist. measurem. (RL)
  • Motorized
  • Automatic Target Recognition (ATR)
  • PowerSearch (PS)
  • Guide Light (EGL)
  • Remote Control Unit / RadioHandle (optional)
  • SmartStation (ATX1230) (optional)

 

Leica TCRP1203+ R400 Spesification

General data

Telescope

Magnification 30x
Free objective aperture 40 mm
Field of view 1°30’ (1.66 gon) / 2.7 m at 100 m
Focusing range 1.7 m to infinity
Keyboard and Display
Display 1/4 VGA (320 x 240 pixels), graphic LCD, illumination, touch screen
Keyboard 34 keys (12 function keys, 12 alphanumeric keys), illumination
Angle display 360° ’ ’’, 360° decimal, 400 gon, 6400 mil, V%
Distance display meter, int. ft, int. ft/inch, US ft, US ft/inch
Data storage
Internal memory 32 MB (optional)
Memory card CompactFlash cards (32 MB and 256 MB)
Number of data records 1750 / MB
Interfaces RS232 and Bluetooth
Circular Level 6’ / 2 mm
Laser plummet
Centering accuracy 1.5 mm at 1.5 m
Laser dot diameter 2.5 mm at 1.5 m
Endless drives
Number of drives 1 horizontal / 1 vertical
Weight 4.8 – 5.5 kg
Environmental specifications
Working temperature range –20°C to +50°C
Storage temperature range –40°C to +70°C
Dust / water IP54
Humidity 95%, non-condensing

Angle measurement

Accuracy 3’’ (1 mgon)
Method Absolute, continuous, diametrical
Compensator
  • Working range: 4’ (0.07 gon)
  • Setting accuracy: 1.0’’ (0.3 mgon)
  • Method: centralized dual axis compensator

Distance measurement (IR)

Range
  • Round prism (GPR1): 3000 m
  • 360° reflector (GRZ4): 1500 m
  • Mini prism (GMP101): 1200 m
  • Reflective tape (60 mm x 60mm): 250 m
  • Shortest measurable distance: 1.5 m
Accuracy / Measurement time
  • Standard mode: 2 mm + 2 ppm / typ. 1.5 s
  • Fast mode: 5 mm + 2 ppm / typ. 0.8 s
  • Tracking mode: 5 mm + 2 ppm / typ. < 0.15 s
  • Display resolution: 0.1 mm
Method Phase measurement (coaxial, invisible infrared laser)

Automatic Target Recognition (ATR)

Range ATR mode / LOCK mode
  • Round prism (GPR1): 1000 m / 800 m
  • 360° reflector (GRZ4): 600 m / 500 m
  • Mini prism (GMP101): 500 m / 400 m
  • Reflective tape (60 mm x 60mm): 55 m (175 ft)
  • Shortest measurable distance: 1.5 m / 5 m
Accuracy / Measurement time
  • Positioning accuracy: < 2 mm
  • Measurement time: 3 – 4 s
Maximum speed (LOCK mode)
  • Tangential (standard mode): 5 m / s at 20 m, 25 m / s at 100 m
  • Radial (tracking mode): 4 m / s
Method Digital image processing (laser beam)

PowerSearch (PS)

Range
  • Round prism (GPR1): 200 m
  • 360° reflector (GRZ4): 200 m (perfectly aligned to instrument)
  • Mini prism (GMP101): 100 m
  • Shortest distance: 5 m
Typical search time < 10 s
Rotating speed Max. 45° / s
Method Digital signal processing (rotating laser fan)

PinPoint R400 reflectorless distance measurement (RL-Mode)

Range
  • 400 m / 200 m (Kodak gray card: 90% reflective / 18% reflective)
  • Shortest measurable distance: 1.5 m
  • Long range to round prism (GPR1): 1000 m - 7500 m
Accuracy / Measurement time
  • Reflectorless < 500 m: 2 mm + 2 ppm / typ. 3 - 6 s, max. 12 s
  • Reflectorless > 500 m: 4 mm + 2 ppm / typ. 3 - 6 s, max. 12 s
  • Long range: 5 mm + 2 ppm / typ. 2.5 s, max. 12 s
Laser dot size
  • At 30 m: Approx. 7 mm x 10 mm
  • At 50 m: Approx. 7 mm x 20 mm
Method System analyzer (coaxial, visible red laser)